
HPLC Columns
- (4)
- (1)
- (16)
- (9)
- (3)
- (3)
- (5)
- (18)
- (6)
- (5)
- (6)
- (1)
- (2)
- (10)
- (250)
- (1)
- (1)
- (2)
- (9)
- (304)
- (10)
- (2)
- (2)
- (1)
- (1)
- (1)
- (205)
- (1,347)
- (4)
- (4)
- (162)
- (1)
- (1)
- (83)
- (20)
- (9)
- (90)
- (900)
- (1)
- (13)
- (2)
- (162)
- (12)
- (4)
- (440)
- (17)
- (1,597)
- (2)
- (2)
- (8)
- (1)
- (86)
- (7)
- (35)
- (2)
- (9)
- (3)
- (30)
- (9)
- (83)
- (1)
- (25)
- (1)
- (9)
- (10)
- (11)
- (5)
- (320)
- (222)
- (1)
- (789)
- (7)
- (1)
- (1)
- (146)
- (459)
- (971)
- (1)
- (56)
- (1)
- (72)
- (53)
- (1)
- (351)
- (25)
- (811)
- (114)
- (1)
- (21)
- (101)
- (1)
- (223)
- (24)
- (2)
- (3)
- (10)
- (1)
- (2)
- (10)
- (11)
- (2)
- (241)
- (63)
- (1)
- (728)
- (12)
- (1)
- (9)
- (15)
- (2)
- (3)
- (130)
- (1)
- (11)
- (5)
- (16)
- (2)
- (3)
- (27)
- (39)
- (87)
- (440)
- (25)
- (2)
- (33)
- (3)
- (13)
- (167)
- (29)
- (15)
- (12)
- (6)
- (139)
- (446)
- (13)
- (4)
- (1,129)
- (30)
- (22)
- (3)
- (2)
- (1)
- (80)
- (24)
- (2,873)
- (10)
- (5)
- (2)
- (24)
- (2)
- (24)
- (17)
- (27)
- (5)
- (4)
- (1)
- (1)
- (4)
- (1,181)
- (3)
- (1)
- (4)
- (4)
- (456)
- (19)
- (648)
- (18)
- (276)
- (3)
- (12)
- (2)
- (144)
- (261)
- (5)
- (141)
- (2)
- (13)
- (141)
- (450)
- (49)
- (125)
- (5)
- (70)
- (5)
- (6)
- (3)
- (63)
- (5)
- (191)
- (11)
- (7)
- (8)
- (6)
- (84)
- (3)
- (1)
- (5)
- (147)
- (1)
- (1)
- (629)
- (22)
- (89)
- (7)
- (7)
- (13)
- (11)
- (412)
- (41)
- (105)
- (35)
- (14)
- (131)
- (11)
- (2)
- (2)
- (13)
- (210)
- (77)
- (10)
- (1)
- (227)
- (2)
- (8)
- (45)
- (3,451)
- (65)
- (13)
- (3)
- (1)
- (1)
- (9)
- (7)
- (3)
- (29)
- (83)
- (31)
- (2)
- (11)
- (4)
- (71)
- (1)
- (4)
- (4)
- (1)
Filtered Search Results

Thermo Scientific™ Hypersil™ BDS C8 Column, 3μm
For a high-quality, base-deactivated, fully endcapped phase with similar selectivity to C18 but slightly less retention, use Thermo Scientific™ Hypersil™ BDS C8 HPLC Columns.
Pore Size | 130 Å |
---|---|
Stationary Phase | C8 |
Temperature | 60°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
Surface Area | 170 m²/g |
Max. Pressure | 5800 psi (400 bar) |
Column Format | Analytical Column |
Particle Size | 3 μm |
Carbon Load | 7% |
Packing Material | Spherical, Fully Porous, Base-Deactivated Silica |
pH | 2 to 8 |
USP Type | L7 |
Thermo Scientific™ Hypersil GOLD™ PEI HILIC HPLC Columns

Retain highly polar and hydrophilic analytes, which are difficult to analyze with conventional C18 columns, using Hypersil GOLD PEI HILIC LC Columns.
Pore Size | 175 Å |
---|---|
Carbon Load | 6% |
Stationary Phase | Polyethyleneimine |
Temperature | 60°C |
Phase | HILIC |
Endcapped | No |
Column Type | HILIC |
pH | 2 to 8 |
Surface Area | 220 m²/g |
Thermo Scientific™ HyPURITY™ C18 Columns, 3μm Particle Size
High quality, highly pure silica columns
Pore Size | 190 Å |
---|---|
Particle Size | 3 μm |
Carbon Load | 13% |
Stationary Phase | C18 |
Phase | Reversed Phase |
Endcapped | Yes |
Packing Material | Silica |
Column Type | Reversed Phase |
pH | 1 to 9 |
Surface Area | 200 m²/g |
USP Type | L1 |
Thermo Scientific™ Hypersil GOLD™ PFP HPLC Columns

Use for analyzing difficult-to-resolve mixtures of halogenated compounds including pesticides.
Pore Size | 175 Å |
---|---|
Carbon Load | 8% |
Temperature | 60°C |
Endcapped | Yes |
Column Type | Reversed Phase |
pH | 2 to 8 |
Surface Area | 220 m²/g |
USP Type | L43 |
Thermo Scientific™ Accucore™ Vanquish™ C18+ UHPLC Columns, 1.5μm
Use the 1.5μm solid core particles of these columns with the Vanquish UHPLC system for unique high-efficiency, high-resolution analyses.
Pore Size | 80 Å |
---|---|
Particle Size | 1.5 μm |
Carbon Load | 6.5% |
Stationary Phase | C18 |
Temperature | 70°C |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
Diameter (Metric) | 2.1 mm |
pH | 2 to 9 |
Surface Area | 110 m²/g |
USP Type | L1 |
Thermo Scientific™ POROS™ CaptureSelect™ LC Lambda Affinity Column, 2.1 x 30 mm
Analytical groups supporting biologic drug development require rapid, sensitive, and precise methods for protein quantitation from cell culture, fermentation harvests, or purification intermediates.
Thermo Scientific™ Hypersil™ BDS 3μm C18 Columns
A good choice for QA/QC labs as a robust, general-purpose column in applications where reproducibility and long column lifetimes are required
Pore Size | 130 Å |
---|---|
Particle Size | 3 μm |
Carbon Load | 11% |
Stationary Phase | C18 |
Phase | Reversed Phase |
Endcapped | Yes |
Column Type | Reversed Phase |
Surface Area | 170 m²/g |
USP Type | L1 |
Thermo Scientific™ ProPac™ 3R SAX 3 μm HPLC Columns
Get the performance you need with ProPac™ 3R SAX HPLC columns. Suitable for charge variant separations and recommended for therapeutic proteins, mAbs, ADCs, and AAVs.
Pore Size | Nonporous |
---|---|
Particle Size | 3 μm |
Stationary Phase | Proprietary |
Temperature | Ambient to 60°C |
Phase | Strong Anion Exchange |
Packing Material | Monodisperse Polymer Resin |
Column Type | Ion Exchange |
pH | 2 to 12 |
Technique | Bio-LC |
Max. Pressure | 4500 psi (310 bar) |
Product Line | ProPac |
Column Format | Analytical Column |
Thermo Scientific™ ProPac™ SCX-10 HPLC Columns
Separate protein variants in difficult matrices using ProPac SCX-10 LC Columns, which provide exceptionally high resolution.
Pore Size | Nonporous |
---|---|
Particle Size | 10 μm |
Stationary Phase | Sulfonate |
Temperature | 60°C |
Phase | Ion Exchange |
Column Type | Ion Exchange |
pH | 2 to 12 |
Product Line | ProPac |
Thermo Scientific™ Acclaim™ Carbamate HPLC Columns
Achieve baseline separation of carbamate specified in U.S. EPA Method 531.2 with high-efficiency Thermo Scientific™ Acclaim™ Carbamate LC Columns.
Pore Size | 120 Å |
---|---|
Stationary Phase | Proprietary |
Temperature | 60°C |
Endcapped | Yes |
Column Type | Specialty/Application Specific |
pH | 3 to 7 |
Surface Area | 300 m²/g |
Product Line | Acclaim |
Thermo Scientific™ Acclaim™ HILIC-10 HPLC Columns
Use this HILIC column to retain and separate highly polar molecules that are unretained by reversed-phase chromatography.
Pore Size | 120 Å |
---|---|
Carbon Load | 8% |
Stationary Phase | Proprietary |
Temperature | 70°C |
Phase | HILIC |
For Use With | LC/MS |
Endcapped | Yes |
Column Type | HILIC |
pH | 2 to 8 |
Surface Area | 300 m²/g |
Product Line | Acclaim |
Thermo Scientific™ ProPac™ HIC-10 HPLC Columns

Achieve high-resolution separation of proteins and peptides under nondenaturing conditions with Thermo Scientific™ ProPac™ HIC-10 LC Columns.
Pore Size | 300 Å |
---|---|
Particle Size | 5 μm |
Stationary Phase | Amide/Ethyl |
Temperature | 40°C |
Phase | Hydrophobic Interaction |
Packing Material | Spherical, Fully Porous, Ultrapure Silica |
Column Type | Hydrophobic Interaction |
pH | 2.5 to 7.5 |
Green Features | Responsibly packaged |
Material | Stainless Steel |
Surface Area | 100 m²/g |
Max. Pressure | 3500 psi (240 bar) |
Thermo Scientific™ MAbPac™ Protein A Antibody Analysis and Purification HPLC Column, 12 μm, 4 mm x 35 mm
Column Format: Analytical Column; Pore Size: Nonporous; Column Phase: Affinity Separation
Thermo Scientific™ GlycanPac™ AXH-1 HPLC Columns
Use this glycan analysis column for qualitative, quantitative, and structural characterization of uncharged and charged glycans present in biological molecules.
Phase | HILIC and Ion Exchange |
---|---|
Column Type | Mixed Mode |
pH | 2 to 8 |
Particle Shape | Spherical silica |
Thermo Scientific™ μPAC™ Neo Low-Load Trapping Columns
Combine Thermo Scientific™ μPAC™ Neo trapping columns with Thermo Scientific™ μPAC™ Neo low-load HPLC columns for optimal performance of bottom-up proteomics experiments.